Schneider Electric ComPacT NSX circuit breaker, rated 160 A. Circuit breaker, ComPacT NSX250R, 200kA/415VAC, 4 poles, MicroLogic 6.2E trip unit 160A.
Circuit breaker, ComPacT NSX250R, 200kA/415VAC, 4 poles, MicroLogic 6.2E trip unit 160A. Genuine Schneider Electric product supplied by United Force.
| Range | ComPacT |
|---|---|
| Product name | ComPacT NSX |
| Device short name | NSX250R |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 4D · 3D + OSN · 3D + N/2 · 3D |
| Neutral position | Left |
| [In] rated current | 160 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| Breaking capacity | 200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 · 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 · 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 · 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity code | R 200 kA 415 V AC |
| Trip unit name | MicroLogic 6.2 E |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSIG |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service breaking capacity | 200 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 200 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 200 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 · 80 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 · 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 · 45 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 · 10000 cycles at 440 V In · 10000 cycles at 690 V In/2 · 5000 cycles at 690 V In |
| Power dissipation per pole | 17.6 W |
| Mounting support | Backplate |
| Mounting position | Horizontal and vertical · Flat on the back |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (long time) · S : for short time short-circuit protection · I : for instantaneous short-circuit protection · G : for ground fault protection |
| Trip unit rating | 160 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 63...160 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time delay adjustment range | 15…400 s at 1.5 x Ir · 0.5…16 s at 6 x Ir · 0.35…11 s at 7.2 x Ir |
| Neutral protection setting | 0.5 x Ir (3D + N/2) · 1 x Ir (4D) · 1.6 x Ir (3D + OSN) · No protection (3D) |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable 5 settings |
| [tsd] short-time delay adjustment range | 0…0.4 s I²t=off · 0.1…0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |