Excl. VAT · +15% added at checkout · Bulk pricing from 10+ units
Min order 1 · sold individually · pack of 1
100% genuine
5-day delivery
7-day returns · 14-day exchange
Secure payment
Trusted Partnerships
Schneider Electric variable speed drive. variable speed drive, Altivar Machine ATV320, 4kW, 200 to 240V, 3 phases, compact.
variable speed drive, Altivar Machine ATV320, 4kW, 200 to 240V, 3 phases, compact. Genuine Schneider Electric product supplied by United Force.
| Range of product | Altivar Machine ATV320 |
|---|---|
| Product or component type | Variable speed drive |
| Product specific application | Complex machines |
| Variant | Standard version |
| Format of the drive | Compact |
| Mounting mode | Wall mount |
| Communication port protocol | Modbus serial · CANopen |
| Option card | Communication module, CANopen · Communication module, EtherCAT · Communication module, Profibus DP V1 · Communication module, PROFINET · Communication module, Ethernet Powerlink · Communication module, EtherNet/IP · Communication module, DeviceNet |
| [Us] rated supply voltage | 200...240 V - 15...10 % |
| nominal output current | 17.5 A |
| Motor power kW | 4.0 kW for heavy duty |
| Motor power hp | 5 hp |
| EMC filter | Without EMC filter |
| IP degree of protection | IP20 |
| Discrete input number | 7 |
| Discrete input type | STO safe torque off, 24 V DC, impedance: 1.5 kOhm · DI1...DI6 logic inputs, 24 V DC (30 V) · DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
| Discrete input logic | Positive logic (source) · Negative logic (sink) |
| Discrete output number | 3 |
| Discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA · Open collector DQ- 0…1 kHz 30 V DC 100 mA |
| Analogue input number | 3 |
| Analogue input type | AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits · AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits · AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
| Analogue output number | 1 |
| Analogue output type | Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits · Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Relay output type | Configurable relay logic R1A 1 NO electrical durability 100000 cycles · Configurable relay logic R1B 1 NC electrical durability 100000 cycles · Configurable relay logic R1C · Configurable relay logic R2A 1 NO electrical durability 100000 cycles · Configurable relay logic R2C |
| Maximum switching current | Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC · Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC · Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC · Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC · Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC · Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
| Minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
| Method of access | Slave CANopen |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points · Flux vector control without sensor, standard · Voltage/frequency ratio - Energy Saving, quadratic U/f · Flux vector control without sensor - Energy Saving · Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor |
| Maximum output frequency | 0.599 kHz |
| Acceleration and deceleration ramps | Linear · U · S · CUS · Ramp switching · Acceleration/deceleration ramp adaptation · Acceleration/deceleration automatic stop with DC injection |
| Motor slip compensation | Automatic whatever the load · Adjustable 0...300 % · Not available in voltage/frequency ratio (2 or 5 points) |
| Switching frequency | 2...16 kHz adjustable · 4...16 kHz with derating factor |
| Nominal switching frequency | 4 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Line current | 23.8 A at 200 V (heavy duty) · 19.9 A at 240 V (heavy duty) |
| Maximum input current | 23.8 A |
| Maximum output voltage | 240 V |
| Apparent power | 8.3 kVA at 240 V (heavy duty) |
| Network frequency | 50...60 Hz |
| Relative symmetric network frequency tolerance | 5 % |
| Prospective line Isc | 5 kA |
| Base load current at high overload | 17.0 A |