| Device short name | ATV212 |
|---|---|
| Product destination | Asynchronous motors |
| Network number of phases | 3 phases |
| Motor power kW | 1.5 kW |
| Motor power hp | 2 hp |
| Supply voltage limits | 323…528 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Line current | 2.5 A at 480 V · 3.2 A at 380 V |
| Range of product | Altivar 212 |
| Product or component type | Variable speed drive |
| Product specific application | Pumps and fans in HVAC |
| Communication port protocol | APOGEE FLN · BACnet · Modbus · LonWorks · METASYS N2 |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| EMC filter | Class C2 EMC filter integrated |
| IP degree of protection | IP21 |
| Apparent power | 2.8 kVA at 380 V |
| Continuous output current | 3.7 A at 380 V · 3.7 A at 460 V |
| Maximum transient current | 4 A for 60 s |
| Speed drive output frequency | 0.5…200 Hz |
| Speed range | 1…10 |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Local signalling | 1 LED (red) for DC bus energized |
| Output voltage | <= power supply voltage |
| Isolation | Electrical between power and control |
| Type of cable | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR · Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC · With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| Electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / 14 AWG · L1/R, L2/S, L3/T: terminal 6 mm² / 10 AWG |
| Tightening torque | 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T) · 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection · Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection |
| Sampling duration | 2 ms +/- 0.5 ms F discrete · 2 ms +/- 0.5 ms R discrete · 2 ms +/- 0.5 ms RES discrete · 3.5 ms +/- 0.5 ms VIA analog · 22 ms +/- 0.5 ms VIB analog |
| Response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s) · FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) · FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) · RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
| Accuracy | +/- 0.6 % (VIA) for a temperature variation 60 °C · +/- 0.6 % (VIB) for a temperature variation 60 °C · +/- 1 % (FM) for a temperature variation 60 °C |
| Linearity error | VIA: +/- 0.15 % of maximum value for input · VIB: +/- 0.15 % of maximum value for input · FM: +/- 0.2 % for output |
| Analogue output type | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits · FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
| Discrete output type | Configurable relay logic: (FLA, FLC) NO - 100000 cycles · Configurable relay logic: (FLB, FLC) NC - 100000 cycles · Configurable relay logic: (RY, RC) NO - 100000 cycles |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) · 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) · 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) · 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
| Discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm · R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm · RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
| Discrete input logic | Positive logic (source) (F, R, RES), = 11 V (state 1) · Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1) |
| Dielectric strength | 3535 V DC between earth and power terminals · 5092 V DC between control and power terminals |
| Insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
| Frequency resolution | Display unit: 0.1 Hz · Analog input: 0.024/50 Hz |
| Communication service | Read device identification (43) · Time out setting from 0.1 to 100 s · Monitoring inhibitable · Write single register (06) · Read holding registers (03) 2 words maximum · Write multiple registers (16) 2 words maximum |
| Option card | Communication card for LonWorks |
| Power dissipation in W | 78 W |
| Air flow | 27 m3/h |