Schneider Electric variable speed drive. Variable speed drive, Altivar HVAC ATH200, ATH230, 0.55kW, 0.75hp, 380 to 500V, 3 phase, IP20, with EMC filter.
Variable speed drive, Altivar HVAC ATH200, ATH230, 0.55kW, 0.75hp, 380 to 500V, 3 phase, IP20, with EMC filter. Genuine Schneider Electric product supplied by United Force.
| Range of product | Altivar HVAC ATH200 |
|---|---|
| Product specific application | HVAC |
| Product or component type | Variable speed drive |
| Variant | Standard version |
| Device short name | ATH230 |
| Product destination | Asynchronous motors · Synchronous motors |
| Mounting mode | Cabinet mount |
| IP degree of protection | IP20 |
| Network number of phases | 3 phases |
| [Us] rated supply voltage | 380...500 V - 15...10 % |
| Relative symmetric mains voltage tolerance | 10 % |
| Supply frequency | 50...60 Hz - 5...5 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 1.9 A |
| Maximum transient current | 2.1 A |
| Motor power kW | 0.55 kW |
| Motor power hp | 0.75 hp |
| Safety function | STO (safe torque off) |
| Safety level | SIL 3 conforming to IEC 61508 · PL = e conforming to ISO 13849-1 |
| EMC filter | Class C2 EMC filter integrated |
| Communication port protocol | Modbus serial · BACnet MS/TP |
| Option card | Communication module for BACnet IP |
| Apparent power | 1.9 kVA at 500 V |
| Power dissipation in W | 27 W |
| Discrete input number | 7 |
| Discrete input type | STO safe torque off, 24 V DC, impedance: 1.5 kOhm · DI1...DI6 logic inputs, 24 V DC (30 V) · DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
| Discrete input logic | Positive logic (source) · Negative logic (sink) |
| Discrete output number | 1 |
| Discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA · Open collector DQ- 0…1 kHz 30 V DC 100 mA |
| Analogue input number | 3 |
| Analogue input type | AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits · AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits · AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
| Analogue output number | 1 |
| Analogue output type | Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits · Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Relay output number | 2 |
| Relay output type | Configurable relay logic R1A 1 NO electrical durability 100000 cycles · Configurable relay logic R1B 1 NC electrical durability 100000 cycles · Configurable relay logic R1C · Configurable relay logic R2A 1 NO electrical durability 100000 cycles · Configurable relay logic R2C |
| Maximum switching current | Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC · Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC · Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC · Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC · Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC · Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
| Minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
| Physical interface | 2-wire RS 485 |
| Connector type | RJ45 |
| Method of access | Server Modbus serial · Subordinate BACnet MS/TP |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps · 9.6, 19.2, 38.4, 76.8 kbit/s |
| Transmission frame | RTU · MS/TP |
| Number of addresses | 0…247 · 0…127 |
| Data format | 8 bits, configurable odd, even or no parity 1or 2 stop |
| Type of polarization | No impedance |